Fire Sprinkler Calculation Software Free Download
Sep 25, 2015 - fire sprinkler design software free download. Sprinkler System Graphic Analyzer Pipes is a desktop system which analyzes an Autocad drawing.
Hvac software - FIRE - Fire Sprinkler Hydraulic Calculations - Elite Software FIRE FEATURES • The pipe material data used in FIRE can be edited. Data is provided for 30 different pipe materials in FIRE.
However, there is now provision for up to 50 pipe materials. You may revise or delete existing pipe material data, or you may add new ones. • FIRE can automatically size the pipes in the sprinkler system if so desired. Sizing can be performed to make sure velocities and desired pressure drops per 100 feet of pipe aren’t exceeded. • The global editor function has been changed so that it can make multiple changes at once to a given range of pipes and nodes. • Tree and Grid Builder give various dimensions concerning a desired tree or grid system, FIRE can automatically create and number all the pipes and sprinklers in a new or existing pipe network.
This feature greatly reduces the amount of tedious data entry reqired to create a pipe network. • Backwards compatible with FIRE for DOS - easily convert old DOS FIRE projects to Window projects. Users now can choose data from built-in NFPA tables for some input data entries. • Fast program and calculation execution. • Main calculation results can now be shown immediately on the screen after calculation for quick preview. • Instantly evaluate your project for error checking and input data.
• Customizable color Supply/Demand Graph • English or Metric units • NFPA style, high quality color presentation reports Elite's FIRE Program quickly performs all necessary hydraulic calculations as required by the National Fire Protection Association (NFPA 13 1996 Edition). FIRE also estimates sprinkler head requirements, calculates optimal pipe sizes, and automatically performs a peaking analysis. FIRE can handle all types of sprinkler systems (trees, grids, and hybrids) with up to 1,000 or more sprinklers and pipes. Meters and standpipes can also be analyzed. FIRE calculates the gpm water flow and velocity through all pipe sections, the gpm flow and residual pressure at each sprinkler head, the pressure losses incurred in each pipe section due to both friction and elevation changes, the maximum system demand pressure, and the total water gpm demanded by the system.
The report format is designed to aid both the designer and the plan reviewer. Free Update FIRE now has the capability to handle a fire pump at or near the inflow point of the the system.

FIRE also can calculate using metric units. These are highly significant and useful new features for FIRE. This is a free update for existing users; call us at (979) 846-2340 for more information on obtaining your update. ©2000 Elite Software Development, Inc., .
Powerful and affordable hydraulic calculation software for automatic fire sprinkler systems. SHC has all the features you need to enter system data, evaluate results, and produce professional hydraulic calculation reports. Calculations use the Hazen-Williams or Darcy-Weisbach friction loss formula.
Wet, dry, preaction, tree, loop, gridded, and custom systems may all be calculated. Multiple water sources, multiple booster pumps, multiple fixed loss devices, negative elevations, SI and U.S. Units, automatic peaking, and velocity pressures are all supported. You may also create custom pipe diameters, fitting equivalent lengths, and liquid properties. SHC's modern syntax highlighting editor allows you to enter sprinkler system data efficiently with input flexibility most programs lack.
Errors are highlighted in real time. There are 'Pop-up helpers' for material and fitting codes so you don't have to memorize them. Automatic 'proposals' anticipate the next parameter and type it for you. Users may enter lengths and elevations using the foot and inch symbols. Group editing makes it easy to change all values of a specific type in your selection, such as k-factors or discharges. SHC even allows pipe and node names up to 8 alphanumeric characters long.
If you think it provides no help, please feel free to follow up. For Visual Basic 6 questions, please read: Best regards, Liliane MSDN Subscriber Support in Forum If you have any feedback on our support, please contact Please mark the replies as answers if they help and unmark them if they provide no help. When you come back, please have a try. Jinzai has given you helpful suggestion. In addition, this forum is for VB.NET questions.
SHC's calculation results window allows you to quickly evaluate your design. All relevant system, pipe, and node data is shown. Data may be sorted by clicking on the column heading. You can customize the pipe information shown. Best of all, the calculation results window can stay open and visible while you make changes in the editor window! Simply resize and drag the results window to a convenient spot on your screen! When your design is done, SHC will print a professional hydraulic calculation report or save it as a pdf file.